ZAIDAN, MUHAMMAD (2018) PERANCANGAN SISTEM KONTROL LEVEL AIR OTOMATIS BERBASIS SENSOR ULTRASONIK DENGAN SISTEM DATA TRANSCEIVER NIRKABEL. Skripsi thesis, Institut Teknologi Dirgantara Adisutjipto.
Text (ABSTRAK)
13010048_ABSTRAK.pdf Download (262kB) |
|
Text (BAB I)
13010048_BAB I.pdf Download (61kB) |
|
Text (DAFTAR PUSTAKA)
13010048_DAFTAR PUSTAKA.pdf Download (83kB) |
|
Text (FULL SKRIPSI)
13010048.pdf Restricted to Repository staff only Download (4MB) |
Abstract
This research concentrated on automatic water level control system based ultrasonic sensors. The automatic water level control system is question is a system which can be controlled of water level, in order to water level in the water tank storage remain at the required level. The automatic control system water level be made to applies method based on sensor for replace manual method. The application of method based sensor is question is to use ratio magnitude of the distance wich signed by sesnsor as information height water level. The created hardware will be applied in prototype form using ultrasonic sensor HC-SR04 as signed of input data, that is water level height data in centimeter unit and display data in pc as output for monitoring water level. The hardware used two water storage tanks, range of sensor to the water storage tank 1 is calibrated at a distance of 14.6 cm with a 5 cm and 10 cm setpoint. Based on the results testing and observation of the whole system on the water level testing data 'upside', calculated average error of the water level comparation in the ruler to the LCD of 1.59 % and an avarage error of the water level comparation in the ruler to the water level on the water monitorring of 3.11 %. On the water level testing data 'down sides', calculated an average error of the water level comparation in the ruler to the LCD of 1.68 % and an avarage error of the water level comparation in the ruler to the water level on the water monitorring of 1.86 %. The magnitude of the maximum and minimum water level that readble on the ruler against setting of setpoint in the arduino program is (setpoint ≤ 5 cm, on the ruler sacale reads 5.2 cm with an error of 4% and setpoint ≥ 10 cm, on the ruler scale reads 9.8 cm with error of 2.04%). Xbee connectivity for indoor testing was able to send and received data at maximum distance 35 m. While outdoor testing the Xbee able to send and receive data at maximum distance 140 m
Item Type: | Thesis (Skripsi) |
---|---|
Subjects: | T Technology > T Technology (General) |
Divisions: | Institut Teknologi Dirgantara Adisujtipto > Teknik Elektro |
Depositing User: | Mr MUHAMMAD ZAIDAN |
Date Deposited: | 20 Aug 2024 07:55 |
Last Modified: | 20 Aug 2024 07:55 |
URI: | http://eprints.stta.ac.id/id/eprint/2579 |
Actions (login required)
View Item |
Downloads
Downloads per month over past year