TROUBLESHOOTING SISTEM INDIKASI EXHAUST GAS TEMPERATURE (EGT) PADA PESAWAT MC DONNEL DOUGLAS DC-9

ARIF BUDIMAN, FADIL (2019) TROUBLESHOOTING SISTEM INDIKASI EXHAUST GAS TEMPERATURE (EGT) PADA PESAWAT MC DONNEL DOUGLAS DC-9. Tugas Akhir thesis, Institut Teknologi Dirgantara Adisutjipto.

[img] Text (ABSTRAK)
16360030_ABSTRAK.pdf

Download (183kB)
[img] Text (BAB I)
16360030_BAB I.pdf

Download (270kB)
[img] Text (DAFTAR PUSTAKA)
16360030_DAFTAR PUSTAKA.pdf

Download (232kB)
[img] Text (FULL SKRIPSI)
16360030.pdf
Restricted to Repository staff only

Download (2MB)

Abstract

EGT is one of the important indicators in the operation of aircraft engines. If the EGT has increased in temperature beyond the specified limit, it can cause damage or overheat to the engine. The measurement of EGT is done by placing the temperature sensor on the turbine outlet temperature called thermocouple. There is a problem that occurs in the EGT indication system that is the EGT indicator pointer needle is not functioning. This problem is caused by the failure of a component in the DC-9 aircraft EGT indication system. This failure can be corrected by identifying, troubleshooting, and testing and checking the overall system of EGT indications. The initial step to troubleshoot the EGT indication system is to identify failures and find out the possible causes that occur, namely the thermocouple leads and the EGT indicators are damaged. To correct this, test the resistance of the thermocouple leads on the back of the EGT indicator. The results of resistance obtained by the authors are the absence of a multimeter designation. The next possible cause is the open balancing resistor. To correct this, test the continuity of the balancing resistor terminal. Then make a replacement on the balancing resistor and calibrate the component. After performing the troubleshoot steps above, an EGT indication system failure location on the McDonnel Douglas DC-9 can be generated and the resistance and continuity balancing resistor are not connected. To correct this, we do a replacement balancing resistor then calibrate the component.

Item Type: Thesis (Tugas Akhir)
Subjects: T Technology > T Technology (General)
Divisions: Institut Teknologi Dirgantara Adisujtipto > D3 Aeronaitika