ANALISIS KINERJA “MINI COOLING TOWER” TIPE INDUCED-DRAFT COUNTERFLOW DENGAN VARIASI WAKTU PENGUJIAN MENGGUNAKAN BAHAN PENGISI (FILL) PLASTIK BERGELOMBANG

PRASETYA WIBOWO, AREL (2020) ANALISIS KINERJA “MINI COOLING TOWER” TIPE INDUCED-DRAFT COUNTERFLOW DENGAN VARIASI WAKTU PENGUJIAN MENGGUNAKAN BAHAN PENGISI (FILL) PLASTIK BERGELOMBANG. Skripsi thesis, Institut Teknologi Dirgantara Adisutjipto.

[img] Text (ABSTRAK)
16040045_ABSTRAK.pdf

Download (94kB)
[img] Text (BAB I)
16040045_BAB I.pdf

Download (119kB)
[img] Text (DAFTAR PUSTAKA)
16040045_DAFTAR PUSTAKA.pdf

Download (61kB)
[img] Text (FULL SKRIPSI)
16040045.pdf
Restricted to Repository staff only

Download (1MB)

Abstract

Cooling towers generally represent the most economical atmospheric heat disposal systems. In normal operation, water constantly circulates by taking the heat contained from the heat transfer process. After water gets the heat, the hot water will be pumped towards the top of the tower and dropped downwards towards the container. The evaporative action aims to remove heat from the water by using air support. This study used corrugated plastic filler material so that water and air contact became longer. It is expected to increase the range value, approach and effectiveness of cooling tower. The purpose of this research was to find out the performance of mini cooling tower with variations in test time conducted against the effectiveness of cooling tower and to know the results of comparison of cooling tower performance testing that uses filler and without filler in the difference in test time. The mini cooling tower size is 40cm x 30cm x 90cm, and the water temperature ranges from 40°C. The results showed that the cooling tower performance effectiveness using filler was 78.34 % in the morning, 65.22 % in the afternoon, and 80.93 % in the evening. Meanwhile, the effectiveness without filler was 36.51 % in the morning, 31.32 % in the afternoon, and 42.38 % in the evening. The highest performance occurred at the cooling tower using filler material conducted in the evening with 14.83 °C range value, 3.43 °C approach, 80.93 % effectiveness, and 2,578 kJ/s cooling capacity. The lowest performance occurred at the cooling tower without filler conducted in the afternoon with 3.44 °C range, 7.54 °C approach, 31.32 % effectiveness and 0.598 kJ/s cooling capacity. Conclusion, the best performance is done in mini cooling tower using filler with test time at night because low temperature at night supports the process of maximum heat transfer. Because mini cooling tower using filler with test time at night has a range value of 14.83°C, approach 3.43°C, effectiveness 80.93%, and cooling capacity of 2,578 kJ/s.

Item Type: Thesis (Skripsi)
Subjects: T Technology > T Technology (General)
Divisions: Institut Teknologi Dirgantara Adisujtipto > Teknik Mesin
Depositing User: Mr AREL PRASETYA WIBOWO
Date Deposited: 11 Jun 2024 02:16
Last Modified: 11 Jun 2024 02:16
URI: http://eprints.stta.ac.id/id/eprint/1916

Actions (login required)

View Item View Item

Downloads

Downloads per month over past year