ANALISA LAJU KOROSI GALVANIS MATERIAL FORK DAN FERRULE PADA KOMPONEN NOSE LANDING GEAR

ERVITA SAR, RULY (2022) ANALISA LAJU KOROSI GALVANIS MATERIAL FORK DAN FERRULE PADA KOMPONEN NOSE LANDING GEAR. Skripsi thesis, Institut Teknologi Dirgantara Adisutjipto.

[img] Text (ABSTRAK)
16050015_ABSTRAK.pdf

Download (98kB)
[img] Text (BAB I)
16050015_BAB I.pdf

Download (118kB)
[img] Text (DAFTAR PUSTAKA)
16050015_DAFTAR PUSTAKA.pdf

Download (142kB)
[img] Text (FULL SKRIPSI)
16050015_compressed.pdf
Restricted to Repository staff only

Download (1MB)

Abstract

On inspection of the PK-SFA aircraft, cracks were found on the fork nose landing gear. The position of the Fork is attached to Ferrule, conditions like this are closely related to galvanic corrosion and can trigger cracks or failures in components that can endanger the safety of the aircraft. Corrosion itself is caused by the interaction of metal with metal and the surrounding environment. The purpose of this study was to determine the rate of galvanic corrosion between fork and ferrule materials in 3.5% NaCl media with variations in immersion time using a rectifier. The test object is made into a square shape and then polished to get a clean surface from the coating. Prior to the corrosion test, each component material is tested for composition to determine the type of material. The corrosion rate was analyzed using the weight loss method and the potential difference method. Another test carried out to support this research is the Micro Test of the surface of the material that has been tested for corrosion. The results of the composition test showed that the content of Magnesium (Mg) was 2.087% and Zinc (Zn) was 5.411% and the content of Aluminum (Al) was 90.65% and there were other guiding elements. And produced Grade Al100 for ferrule components. In the Fork component, the carbon content is 0.388% and the Iron (Fe) content is 95.78% and there are other guide elements that are low, then Grade Fe110. The corrosion rate that is generated from the calculation of the potential difference method is for the 4th minute = 0.759 volts/minute, the 6th minute = 0.506 volts/minute, and the 8th minute = 0.379 volts/minute. The value of the corrosion rate obtained by the weight loss method of Al material is 1.057 mmyr, specimen 2 is 709 mmyr, 3 is 2.453 mmyr, and for Fe material, specimen 1 is 1.510 myr, specimen 2 is -2.908 mmyr, specimen 3 amounted to 1.361 mmyr.

Item Type: Thesis (Skripsi)
Subjects: T Technology > T Technology (General)
Divisions: Institut Teknologi Dirgantara Adisujtipto > Teknik Dirgantara
Depositing User: Ms Ruly ervitasari
Date Deposited: 06 May 2024 02:38
Last Modified: 06 May 2024 02:38
URI: http://eprints.stta.ac.id/id/eprint/1636

Actions (login required)

View Item View Item

Downloads

Downloads per month over past year