KIRAN, KIRAN (2022) PENANGANAN DAN ANALISIS KEGAGALAN FUEL ON LOW PRESSURE CONDITION PADA DISTRIBUTION FUEL SYSTEM PESAWAT KT-1B DI SKATEK 043 LANUD ADISUTJIPTO DENGAN MENGGUNAKAN METODE FAULT TREE ANALYSIS. Tugas Akhir thesis, Institut Teknologi Dirgantara Adisutjipto.
Text (ABSTRAK)
18060003_ABSTRAK.pdf Download (181kB) |
|
Text (BAB I)
18060003_BAB I.pdf Download (159kB) |
|
Text (DAFTAR PUSTAKA)
18060003_DAFTAR PUSTAKA.pdf Download (159kB) |
|
Text (FULL SKRIPSI)
18060003_compressed.pdf Restricted to Repository staff only Download (898kB) |
Abstract
The fuel system is the main system that provides and supplies fuel to the engine. One of them is the distribution fuel system which functions to supply fuel from the main tank to the engine, to support normal distribution of fuel, the supporting components must function normally, if one or more components do not work normally, it will affect the fuel. pressure. This study uses the observation method to obtain information on the failure of fuel on low pressure conditions, and the fault tree analysis method is used to observe and analyze the possible causes of the failure based on the troubleshooting procedure manual TO 1T-KT-1B 22. The process of removal/installation refers to and technical order TO1T-KT1B-2-5JG-2. The fuel on low pressure condition is caused by the delivery jet pump component stuck on the valve flap. After knowing the problem, the replacement process for the delivery jet pump component was carried out based on the technical order T.O.1T KT1B-2-5JG-2. After the replacement and functional tests were carried out based on the technical order TO1T-KT1B-2-5JG-2 page 42-1, the result was that the F PRESS light warning on the central warning panel (CWP) did not light up, indicating that fuel pressure had returned to normal. normal pressure. By using fault tree analysis, 19 basic events related to fuel on low pressure conditions were found, namely, (1) insuffiency of fuel quantity, (2) fuel filter leakage, (3) dirty fuel filter, (4) broken fuel flow indicator cable, (5) line pressure problem, (6) delivery line bending, (7) delivery line leakage, (8) connector delivery line problem, (9) thread screw transfer jet pump problem, (10) dirty jet pump transfer filter, (11 ) flap valve problem, (12) thread screw delivery line problem, (13) filter delivery jet pump dirty, (14) electrical source boost pump problem, (15) cable boost pump broken, (16) ashandle maintenance shutoff valve broken, (17) maintenance shutoff valve stuck close, (18) flap valve stuck close, (19) spring flap valve broken.
Item Type: | Thesis (Tugas Akhir) |
---|---|
Subjects: | T Technology > T Technology (General) |
Divisions: | Institut Teknologi Dirgantara Adisujtipto > D3 Aeronaitika |
Depositing User: | Mr kiran kiran |
Date Deposited: | 25 Apr 2024 03:53 |
Last Modified: | 25 Apr 2024 03:53 |
URI: | http://eprints.stta.ac.id/id/eprint/1529 |
Actions (login required)
View Item |
Downloads
Downloads per month over past year